Advanced Search

Content Type

Topics

Publication Date

Architecture Reconstruction Case Study

  • Publish Date:
  • Publisher: Software Engineering Institute
  • SEI Identifier: CMU/SEI-2003-TN-008
  • Type: Technical Note
  • Topics: Software Architecture
  • Description: This report outlines an architecture reconstruction carried out at the SEI on a software system called VANISH, which was developed for prototyping visualizations.

Abstract

This report outlines an architecture reconstruction carried out at the Software Engineering Institute (SEI) on a software system called VANISH that was developed for prototyping visualizations. The goals of the reconstruction were to understand the existing VANISH system and to use a new architecture reconstruction tool, called ARMIN, for the reconstruction, while ensuring that ARMIN has at least the same capabilities as the Dali Architecture Reconstruction Workbench.

During the reconstruction several architectural views were generated through abstraction of low-level information extracted from the system. These views show the components of the system and the interfaces among them. The ARMIN tool provides the ability to visualize, navigate, and manipulate the set of views generated, and yields results technically compatible with the Dali Workbench but with improved presentation and layout.

Cite This Report

Show Citation Formats

SEI

Architecture Reconstruction Case Study (CMU/SEI-2003-TN-008 ). Software Engineering Institute, Carnegie Mellon University, 2003. http://resources.sei.cmu.edu/library/asset-view.cfm?AssetID=6431

IEEE

"Architecture Reconstruction Case Study," Software Engineering Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, Technical Note CMU/SEI-2003-TN-008 , 2003. http://resources.sei.cmu.edu/library/asset-view.cfm?AssetID=6431

APA

(2003). Architecture Reconstruction Case Study (CMU/SEI-2003-TN-008 ). Retrieved October 01, 2014, from the Software Engineering Institute, Carnegie Mellon University website: http://resources.sei.cmu.edu/library/asset-view.cfm?AssetID=6431

CHI

Architecture Reconstruction Case Study (CMU/SEI-2003-TN-008 ). Pittsburgh, PA: Software Engineering Institute, Carnegie Mellon University, 2003. http://resources.sei.cmu.edu/library/asset-view.cfm?AssetID=6431

MLA

2003. Architecture Reconstruction Case Study (Technical Report CMU/SEI-2003-TN-008 ). Pittsburgh: Software Engineering Institute, Carnegie Mellon University. http://resources.sei.cmu.edu/library/asset-view.cfm?AssetID=6431